Level Meter Sensitivity Adjustments

[How to change sensitivity]
Based on purpose of use, types of materials used (i.e. plastics) may vary, but since each has its own characteristics, there will be times when sensitivity will have to be adjusted.
[Adjustment]
  1. Remove cover.
  2. Adjust spring position based on purpose of use.
    • For Full Load Detect: To make meter attain full load readings less often, set spring to "strong" strengthen wing torque.
    • For Full Load Detect: To make meter attain full load readings frequently, set spring to "weak" to weaken wing torque.
    • For Low Material Detect: To make low material readings appear frequently, set spring to "strong" to strengthen wing torque.
    • For Low Material Detect: To make low material readings appear less often, set spring to "weak" to weaken wing torque.
  3. Install cover.